List of Contributors xiii Preface xvii Section A Debonding 1 1 Cutting with Rotating Instruments and Cutting Efficiency of Burs 3 MarÃa Arregui, LluÃs Giner-Tarrida, Teresa Flores, Angélica Iglesias, and Andreu Puigdollers 1.1 Introduction 3 1.2 Enamel Surface and Damage Associated with Debonding Techniques: Burs and Polishing 4 1.2.1 Design and Type of Burs 7 1.2.1.1 Diamond Burs 7 1.
2.1.2 Tungsten Carbide Burs 8 1.2.2 Cutting Efficiency 10 1.2.2.1 Diamond and Carbide Burs 10 1.
2.2.2 Rotating Instruments: Turbines and Electric Motor Handpieces 12 1.2.2.3 Other Factors Related to Cutting Efficiency 14 1.2.3 Effect of the Debonding Technique on the Enamel 16 1.
3 Preservation and Remineralization 19 1.4 Clinical Considerations 20 References 21 2 Debonding Protocols 28 Eser Tüfekçi and William Brantley 2.1 Introduction 28 2.2 Bond Failure Locations during Debonding 29 2.3 Protocols for Bracket Removal 30 2.4 Ultrasonic Debonding 33 2.5 Electrothermal Debonding 33 2.6 Use of Lasers for Debonding 34 2.
7 Guidelines from Manufacturers 36 2.a Appendix: Units for Debonding Stress and Consideration of Debonding Force 37 References 38 3 Bonding and Debonding Considerations in Orthodontic Patients Presenting Enamel Structural Defects 43 Despina Koletsi, T. Gerald Bradley, and Katerina Kavvadia 3.1 Introduction 43 3.2 General Considerations and Challenges of Bonding and Debonding Strategies 44 3.3 Enamel Structural Defects 47 3.3.1 Bonding/Debonding Considerations for AI Subtypes 50 3.
3.2 Enamel Hypoplasia and Molar Incisor Hypomineralisation 52 3.3.3 Fluorosis 56 3.4 Concluding Remarks 58 References 59 4 Enamel Colour, Roughness and Gloss Changes after Debonding 63 Andreas Karamouzos, Effimia Koumpia, and Anastasios A. Zafeiriadis 4.1 Introduction 63 4.2 Tooth Colour Changes Associated with Orthodontic Treatment 66 4.
2.1 Colour Definitions - Vision and Specification 66 4.2.2 Tooth Optical Properties 68 4.2.3 Tooth Colour Measurement and Quantification Thresholds 69 4.2.4 Tooth Colour Changes Related to Orthodontic Treatment 70 4.
2.5 Aetiology of Colour Changes 71 4.2.6 In Vitro vs. In Vivo Studies 72 4.2.7 ÎÎ and CIELAB Colour Parameter Changes 79 4.2.
8 Long-Term Enamel Colour Changes 80 4.2.9 Types of Teeth 80 4.2.10 Gender and Age 81 4.2.11 Etching Pattern 81 4.2.
12 Adhesives 82 4.2.13 Resin Removal Techniques 83 4.2.14 Quality Assessment of Studies 84 4.2.15 Conclusions 86 4.3 Tooth Bleaching Considerations After Debonding 87 4.
4 Enamel Roughness Changes After Debonding 89 4.5 Tooth Gloss Changes After Debonding 94 References 99 5 Aerosol Production during Resin Removal with Rotary Instruments 116 Anthony J. Ireland, Christian J. Day, and Jonathan R. Sandy 5.1 Introduction 116 5.1.1 What Are Airborne Particulates, and Where Might They End Up? 117 5.
1.2 Why Do Airborne Particulates Present a Potential Health Risk? 120 5.1.2.1 Aerodynamic Diameter and Lung Clearance 121 5.1.2.2 Chemical Composition and Solubility 122 5.
1.2.3 Bioaerosols 122 5.1.2.4 Dental Bioaerosols 123 5.1.3 What Are the Occupational Health Risks? 123 5.
1.4 Are Dental Personnel at Risk from Particulate Inhalation? 124 5.1.5 What Is the Evidence that Airborne Particulates Are Created during Orthodontic Appliance Removal with Rotary Instruments? 125 5.1.6 What Are Workplace Exposure Limits (WELs), and How Do Particulates Produced During Orthodontic Debonding Compare with Them? 129 5.1.7 What Methods Can Be Used to Reduce the Orthodontist''s Exposure to Airborne Particulates Produced During Appliance Debonding and Enamel Clean-Up? 131 5.
1.8 What about Bioaerosols Produced During Orthodontic Debond and Enamel Clean-Up? 133 5.1.9 How Can the Risk of Inhalation of Dental Particulates during Orthodontic Debond and Enamel Clean-Up Be Minimised? 135 References 136 6 Evidence on Airborne Pathogen Management from Aerosol-Inducing Practices in Dentistry - How to Handle the Risk 143 Despina Koletsi, Georgios N. Belibasakis, and Theodore Eliades 6.1 Introduction 143 6.2 Existing Evidence 145 6.2.
1 Existing Evidence from Synthesized Data Including Direct and Indirect Comparisons of Interventions 154 6.2.2 Evidence Based on Single Study Estimates 160 6.2.3 Quality and Confidence of Existing Evidence 161 6.3 Findings in Context 161 6.3.1 Use of Chlorhexine (CHX) as Pre-Procedural Mouth Rinse 165 6.
3.2 Alternative Effects and Actions of Povidone Iodine (PI), Ozone (OZ), and Chlorine Dioxide (ClO2) 166 6.3.3 Aerosolized Pathogens and Dental Procedures 168 6.3.4 Strengths and Limitations Stemming from Existing Evidence 170 6.4 Concluding Remarks and Implications for Research 171 References 171 7 Future Material Development for Efficient Debonding 178 Theodore Eliades 7.1 Command-Debond Adhesives 179 7.
2 BPA-Free Monomers 180 7.3 Biomimetic Adhesives 182 Further Reading 183 8 The Use of Attachments in Aligner Treatment: Analyzing the ''Innovation'' of Expanding the Use of Acid Etching- Mediated Bonding of Composites to Enamel and Its Consequences 185 Theodore Eliades, Spyridon N. Papageorgiou, and Anthony J. Ireland 8.1 Enamel Involvement 186 8.2 In Vivo-Induced Alterations of Aligners and Attachments 188 8.3 Release of Compounds 192 8.4 Debonding and Grinding 194 8.
4.1 Aerosol Hazards 194 8.4.2 Xenoestrogenic Action (Bulk and Ground Particles) and Other Biologic Effects 197 8.5 Concluding Remarks 198 References 199 Section B Fixed Retainer Bonding 205 9 Composite Resins Used for Retainer Bonding 207 Iosif Sifakakis 9.1 Introduction 207 9.2 Hardness 208 9.3 Wear Resistance 211 9.
4 Bond Strength 213 9.5 Microleakage 215 9.6 Water Sorption 219 9.7 Ageing 219 References 221 10 Wires Used in Fixed Retainers 227 Iosif Sifakakis, Masahiro Iijima, and William Brantley 10.1 Introduction 227 10.2 Desirable Properties of Retainer Wires 230 10.2.1 Stiffness 230 10.
2.2 Strength 233 10.2.3 Range 234 10.3 Clinical Selection of Retainer Wire 236 10.4 Recent Research 241 References 242 11 Release of Bisphenol-A from Materials Used for Fixed Retainer Bonding 248 Iosif Sifakakis 11.1 Introduction 248 11.2 BPA and Fixed Retainers - Clinical Considerations 250 11.
3 In Vitro Research 252 11.4 BPA-Free Orthodontic Adhesives 253 11.5 Conclusions 255 References 255 12 Clinical Effectiveness of Bonded Mandibular Fixed Retainers 259 Thaleia Kouskoura, Dimitrios Kloukos, Pawel Pazera, and Christos Katsaros 12.1 Introduction 259 12.2 Short-Term Alignment Stabilisation 260 12.3 Long-Term Alignment Stabilisation 262 12.4 Failure Rates 265 12.5 Periodontal Effects 269 12.
6 Side Effects of Fixed Retainers - Unwanted Tooth Movement 272 References 275 13 Masticatory Forces and Deformation of Fixed Retainers 283 Iosif Sifakakis and Christoph Bourauel 13.1 Introduction 283 13.2 Clinical Observations 283 13.3 Retainer Properties 286 13.4 In Vitro Loading of Fixed Retainer Wires 288 References 292 Index 296.